CL17sc Ultra Low Range Colorimetric Chlorine Analyser
Is your dechlorination process optimised? Do you know whether your assets are protected against chlorine damage? Chlorine breakthrough can adversely affect your process, product or equipment.
With its 0 - 20 ppm measuring range, the 9184 sc free chlorine analyser is ideal for drinking water distribution monitoring, chlorination applications, demineralisation systems, and wastewater or cooling water processes.
| Weight | 6.5 kg |
| Flow | Automatic regulation 14 L/h (200 - 250 mL/min) with flow cell |
| Relative humidity | 0 - 90% non-condensing |
| Maintenance interval | Measuring cell: 6 months for membrane and electrolyte in typical application; pH: 1 - 1.5 years in typical application |
| Pressure range | 0.1 - 2 bar in flow cell |
| Accuracy | 2% or ±10 ppb HOCl (whichever is greater, at pH <8) 2% or ±10 ppb TFC (whichever is greater, at pH <7.5) |
| Warranty | 24 aylar |
| Interferences | No interference from chloramines. Chlorine dioxide and ozone may affect measurements. |
| Operating temperature range | 0 - 45 °C |
| Calibration interval | 2 months |
| Calibration method | Zero point calibration: Electrical (automatic) or with chlorine-free water. Calibration: Comparison of laboratory method with process sample. pH calibration: One or two-point calibration using standards, or comparison of laboratory method with process sample |
| What's in the box | 9184sc Chlorine Sensor Panel with pH Sensor, Membranes and Electrolyte and Manual. |
| Mounting | Flat, vertical surface (panel, stand, etc.) |
| Enclosure Rating | IP66 / NEMA 4X |
| Sample outlet | 0.5 inch ID |
| Sample inlet | 0.25 inch OD |
| Sample temperature | 2 - 45 °C |
| Measuring range | 0 - 20 mg/L HOCl |
| Measuring principle | Amperometric/Membrane (electrode, membrane, electrolyte) |
| Measurement frequency | Continuous |
| Parameter | Total Free Chlorine |
| pH Range | 4 - 8 pH; acidification unit available for pH >8 |
| Storage conditions | -20 - 60 °C |
| Detection limit | 0.005 mg/L HOCl |
| Temperature compensation | Automatic over sample temperature range Automatic over sample temperature range |
| Standard deviation | 0.7 % |
| Description | 9184sc Total Free Chlorine Amperometric Sensor |
| Response time | 90% in less than 90 seconds |
| Part No. | Description | Description | Parameter | Measuring range |
|---|---|---|---|---|
| LXV432.99.00001 | 9184sc Toplam Serbest Klor (TFC) amperometrik Analyser | 9184sc Total Free Chlorine Amperometric Sensor | Total Free Chlorine | 0 - 20 mg/L HOCl |
Request a quote for pricing and lead time; you can mention the part number you are interested in your message.
Documents open on the Hach website in a new tab.
With its 0 - 20 ppm measuring range, the 9184 sc free chlorine analyser is ideal for drinking water distribution monitoring, chlorination applications, demineralisation systems, and wastewater or cooling water processes. A minimum detection limit of 5 ppb (hypochlorous chlorine as HOCl at a concentration of 0.005 mg/L) gives the 9184 sc an advantage for near-zero chlorine readings.
The all-inclusive 9184 sc free chlorine system comes pre-assembled on a panel. To get started, simply mount the panel in the desired location, install the sensors and connect the controller. The sensor's membrane system means no reagents are used for measurement. Maintenance requirements are minimal, and typical maintenance items for two years are supplied with the system.
Product code: LXV432.99.00001