| K1100-KTO-P-MET |
Orbisphere K1100 LDO Sensor Kit, 0-2000 ppb, 410 controller, 6 mm flow chamber, panel mount |
Oxygen | | 0 - 2000 ppb dissolved O 2 (DO) | ± 0.8 ppb or 2%, whichever is greater | Single zero point calibration with standard 99.999% nitrogen (grade 5.0) or equivalent oxygen-free gas |
| K1100-KTO-P-IMP |
Orbisphere K1100 LDO Sensor Kit, 0-2000 ppb, 410 controller, ¼ inch flow chamber, panel mount |
Oxygen | | 0 - 2000 ppb dissolved O 2 (DO) | 0.8 ppb or 2%, whichever is greater | Single zero point calibration with standard 99.999% nitrogen (grade 5.0) or equivalent oxygen-free gas |
| K1100-KTO-W-IMP |
Orbisphere K1100 LDO Sensor Kit, 0-2000 ppb, 410 controller, ¼ inch flow chamber, wall mount |
Oxygen | | 0 - 2000 ppb dissolved O 2 (DO) | ± 0.8 ppb or 2%, whichever is greater | Single zero point calibration with standard 99.999% nitrogen (grade 5.0) or equivalent oxygen-free gas |
| K110H-KTO-P-IMP |
Orbisphere K1100 LDO Sensor Kit, 0-40 ppm, 410 controller, ¼ inch flow chamber, panel mount |
Oxygen | | 0 - 40 ppm dissolved O 2 (DO) | 0.02 ppm or 3%, whichever is greater | Two points (zero and air) at cap replacement, one point (air) during use |
| K110H-KTO-W-IMP |
Orbisphere K1100 LDO Sensor Kit, 0-40 ppm, 410 controller, ¼ inch flow chamber, wall mount |
Oxygen | | 0 - 40 ppm dissolved O 2 (DO) | 0.02 ppm or 3%, whichever is greater | Two points (zero and air) at cap replacement, one point (air) during use |
| K1100-S00 |
K1100 LDO sensor for insertion applications, 0-2000 ppb, 28 mm Orbisphere fitting |
Oxygen | | 0 - 2000 ppb dissolved O 2 (DO) (indicative values up to 5000 ppb) | ± 0.8 ppb or 2%, whichever is greater | Single zero point calibration with standard 99.999% nitrogen (grade 5.0) or equivalent oxygen-free gas |
| K1100-KTO-W-MET |
Orbisphere K1100 LDO Sensor Kit, 0-2000 ppb, 410 controller, 6 mm flow chamber, wall mount |
Oxygen | | 0 - 2000 ppb dissolved O₂ (DO) | ± 0.8 ppb or 2%, whichever is greater | Single zero point calibration with standard 99.999% nitrogen (grade 5.0) or equivalent oxygen-free gas |
| K1100-S00H |
K1100 LDO sensor for insertion applications, 0-40 ppm, 28 mm Orbisphere fitting |
Oxygen | | 0 - 40 ppm dissolved O 2 (DO) | ± 0.02 ppm or 3%, whichever is greater | Two points (zero and air) at cap replacement, one point (air) during use |
| K1200-S00 |
Orbisphere K1200 LDO Oxygen sensor, 0 - 2000 ppb, 28 mm Orbisphere fitting |
Oksijen | | 0 - 2000 ppb dissolved O 2 (DO) | ± 0.8 ppb or 2%, whichever is greater | Single zero point calibration with standard 99.999% nitrogen (grade 5.0) or equivalent oxygen-free gas |
| K110H-KTO-W-MET |
Orbisphere K1100 LDO Sensor Kit, 0-40 ppm, 410 controller, 6 mm flow chamber, wall mount |
Oxygen | | 0 - 40 ppm dissolved O 2 (DO) | 0.02 ppm or 3%, whichever is greater | Two points (zero and air) at cap replacement, one point (air) during use |
| K1200-S00H |
Orbisphere K1200 LDO Oxygen sensor, 0 - 40 ppm, 28 mm Orbisphere fitting |
Oksijen | | 0 - 40 ppm dissolved O 2 (DO) | ± 0.02 ppm or 3%, whichever is greater | Two points (zero and air) for cap replacement, one during use (air), with standard 99.9% nitrogen (grade 3.0) or equivalent oxygen-free gas |