Hach · 9610.KTO.S0.XXX

Polymetron 9610sc Silica Analyser

Less Maintenance, Less Downtime. Only two litres of reagent are needed for up to 90 days of unattended analyser operation — twice as long as the 5000 Series.

Weight20 kg without reagents and standards; 36.3 kg with reagents
Flow Rate55 - 300 mL/min
AlarmFour relay outputs; type: unpowered SPDT relays, each rated 5 A resistive, 240 VAC maximum. Connection: 18 to 14 AWG wire, 18 AWG stranded wire recommended.
FittingSample line and sample bypass drain: 6 mm (¼-in.); Air purge inlet: 6 mm (¼-in.); Chemical and enclosure drains: 9.5 mm (3/8-in.)
Dimensions (H x W x D)804 mm x 452 mm x 360 mm
Output4 - 20 mA
Accuracy0 - 500 µg/L: ±1 µg/L or ±1% of reading, whichever is greater; 500 - 5000 µg/L: ±5% (tested with Hach reagents)
Power requirements (Hz)50/60 Hz
Power requirements (Voltage)100 - 240 V AC, 24 V DC
Warranty24 aylar
External sampleGrab sample in and grab sample out feature
Light SourceClass 1M LED (light emitting diode) with 810 nm peak wavelength
Operating humidity5 - 95% non-condensing (indoor use only)
Operating temperature range5 - 45 °C
Number of channels1, 2, 4, 6; programmable sequence
Pollution degree2/II
Controller compatibilitySC200, SC1000
Protection classI
Manual languagesEnglish, French, Spanish, B. Portuguese, Chinese, Japanese, Korean, Thai, German, Italian, C. Portuguese, Czech, Danish, Dutch, Polish, Swedish, Finnish, Bulgarian, Hungarian, Romanian, Lithuanian, Russian, Turkish, Slovak, Slovenian, Croatian, Greek, Estonian
MountingWall, panel or benchtop
Enclosure RatingIP56 / NEMA 4X
Sample pressure0.14 - 6 bar (2 - 87 psi) (for Pressure Regulator Preset)
Sample temperature5 - 50 °C
Measuring range0 - 5000 µg/L as SiO 2
Measuring principleColorimetric
ParameterSilica
Reagent consumption2 L reagent for 90 days with 15-minute measurement time
RelaysFour; type: unpowered SPDT relays, each rated 5 A resistive, 240 VAC maximum
Storage conditions-20 - 60 °C
Detection limit0.5 µg/L
CertificationsCE (EN 61326-1: 2006; EN 61010-1: 2010; EN 60529: 1991, +A1:2000) KC (EN 61326-1: 2006) C-tick (EN 61326-1: 2006) cETLus (UL 61010-1: 2012; NEMA 250: 2003; CSA C22.2 No 61010-1: 2012)
Repeatability± 0.5 µg/L or ± 1% of reading, whichever is greater
Response timeСтандартно, 9.5 минути при 25 °C (77 °F); променящо се според температурата
UygulamaPure water / Power

Product code: 9610.KTO.S0.XXX

Related products

5500 sc Silika Analizörü
Hach

5500 sc Silica Analyser

Less Maintenance, Less Downtime. Only two litres of reagent are needed for up to 90 days of unattended analyser operation — twice as long as the 5000 Series.

Silica Analysers Details →
EZ Series Silica Analysers
Hach

EZ Series Silica Analysers

The EZ sc Series Online Analysers offer multiple options to monitor Silica in water. Typical applications are steam & power generation, surface water, process water. The EZ1000sc Series Analysers use colorimetric analysis to measure Silica.

EZ1035.9800140T Details →