IO9000 Module
IO9004 analog 0/4-20 mA outputs and inputs. The IO9004 offers 3 analog 0/4-20 mA outputs and 2 analog 0/4-20 mA inputs. The outputs transmit sample events or logged data to SCADA systems.
The AS950 AWRS is a rugged, weatherproof sampler with an integrated refrigerator for applications that require temperature control to preserve samples.
| Weight | 86 kg |
| Alarm | Configurable alarms shown on the status screen are recorded in the alarm logs under settings. Alarms can be used to record system diagnostics and events such as program end, sample complete, missed sample and full bottle. Channel alarms are set point alarms for logged measurements (channels) such as pH, level and supply voltage. |
| Base type | 4 mevsim |
| Boyutlar | 76 x 81 x 130 cm (30 x 32 x 51 in.) |
| Vertical Lift | Maximum 8.5 m with 8.8 m of 3/8 inch vinyl intake hose, at sea level and 20 - 25 °C |
| Languages | en, fr, es, it, de, pt, zh, tr, hu, cz, pl, ro, hr, el, sl, sk, fi, ru, ja, ko |
| Status messages | Detects and reports to all systems which program is running, whether a sample was missed, when the next sample will be taken, how many samples remain, the number of logged channels, the last measurement time, available memory, the number of active channels, when alarms were triggered (if any), active sensors and cabinet temperature |
| Display | 1/4 VGA, Colour; auto-prompted/menu-driven program |
| Manual Sampling | Starts sample collection independently of the running program |
| Power requirements (Hz) | 50/60 Hz |
| Power requirements (Voltage) | 115/230 V AC |
| Factory-installable options | TWO SENSOR PORTS: can be used with Hach digital Differential pH, Hach digital AV9000 analyser with submerged area-velocity flow and/or Hach digital US9000 ultrasonic level sensors Please contact your local Hach representative for details. NON-CONTACT LIQUID DETECT for applications requiring full tubing replacement. Sample volume repeatability RAIN/RS485 PORT: can be used with a Hach Rain Gauge (not included) or for RS485 communication |
| Warranty | 24 aylar |
| Inputs | One 0/4-20 mA input for flow pacing |
| Intake rinse | Strainers: PTFE and 316 Stainless Steel construction or all 316 stainless steel in standard sizes; high-velocity and low-profile for shallow applications. Purge: Automatic air purge before and after each sample; duration automatically compensated for changing intake line lengths. Rinse: Intake line automatically rinsed with source liquid 1 to 3 times before each sample. Retries on failure: If no sample is collected on the first attempt, the sample collection cycle is automatically repeated 1 to 3 times |
| Body material | Low-density polyethylene with UV inhibitor (Sampler) |
| Memory | Sample history: 4000 records; Data log: 325,000 records; Event log: 2000 records |
| Hortumlar | Pump tubing: 9.5 mm ID x 15.9 mm OD Silicone. Intake tubing: 1.0 - 4.75 m minimum length, 1/4 inch or 3/8 inch ID Vinyl or 3/8 inch ID PTFE-lined Polyethylene with protective outer cover (black or clear) |
| Communication Capability | USB and optional RS485 (Modbus) |
| Operating mode | Continuous or non-continuous |
| Lock Function | Access code protection prevents tampering with the instrument |
| Pollution degree | 2 |
| User Interface | Membrane switch keypad with 2 multi-function soft keys |
| User interface | Chinese, English, French, German, Italian, Spanish, Portuguese |
| What's in the box | 1 of each: AS950 Controller |
| Model | AS950 AWRS |
| Enclosure material | PC/ABS alloy, NEMA 4X, 6, IP68, corrosion and ice resistant (Controller) |
| Sampling interval | Selectable in single increments from 1 to 9999 flow pulses or in one-minute increments from 1 to 9999 minutes |
| Sampling mode | Pacing: Time weighted, Flow weighted, Time schedule, Flow schedule, Event. Distribution: Single-bottle composite, multi-bottle composite, multi-bottle discrete, bottles per sample, samples per bottle, or a combination of bottles per sample and samples per bottle |
| Sampling trigger | When a flow sensor, pH/temperature sensor or environmental monitoring unit is used and field-selectable limits are exceeded, sampling can be triggered by an upset condition |
| Sample volume | Programmable in 10 mL increments from 10 to 10,000 mL |
| Sample volume accuracy | Typical: ±5% of a 200 mL sample volume with: 4.6 m vertical lift, 4.9 m of 3/8 inch vinyl intake tubing, single bottle, full bottle shut-off at room temperature and 1524 m elevation |
| Sample Volume Repeatability | Typical: ±5% of a 200 mL sample volume with: 4.6 m vertical lift, 4.9 m of 3/8 inch vinyl intake tubing, single bottle, full bottle shut-off at room temperature and 1524 m elevation |
| Sample container | SINGLE BOTTLE: (1) 10 L Glass or Polyethylene or 21 L Polyethylene. MULTIPLE BOTTLES: (2) 10 L Polyethylene or Glass, (4) 10 L Polyethylene or Glass, (8) 2.3 L Polyethylene or 1.9 L Glass, (12) 2 L Polyethylene, (24) 1 L Polyethylene or 350 mL Glass |
| Sample Pump | High-speed peristaltic, dual-roller pump with 0.95 ID x 1.6 OD cm (3/8 inch ID x 5/8 inch OD) pump tubing; IP37 pump body, Polycarbonate cover |
| Sample transport velocity | 0.9 m/s with 4.6 m vertical lift, 4.9 m of 3/8 inch vinyl intake tubing, at 21°C and 1524 m elevation |
| Auto Shut-off | Multiple Bottle Mode: After a full rotation of the distributor arm (unless Continuous Mode is selected). Composite Mode: After a preset number of samples from 1 to 999 has been delivered to the composite container, or upon full container. |
| Pump Flow Rate | 4.8 L/min at 1 m vertical with typical 3/8 inch intake tubing |
| Probes included? | No |
| Programlar | Dual Programming: Up to 2 sample programs can be run consecutively, in parallel or by programmed day of the week, allowing a single sampler to work like multiple samplers |
| Rain Gauge Input | No |
| Clock | ±1 second per day at 25 °C |
| Sensor Ports | 1 |
| Certifications | cETLus (115 V, 60 Hz model), CE (230 V, 50 Hz model) Controller: CE, KC, RCM |
| Temperature | Operating: AWRS: 0 – 50 °C with optional controller compartment heater; AWRS: -40 – 50 °C with controller compartment heater and AC battery backup; AWRS: -15 – 40 °C. Storage: -30 – 60 °C |
| Refrigeration components and plumbing | All copper tubing exposed to harsh conditions is insulated with conformal corrosion protection to prevent sweating and condensation |
| Refrigeration system | Air-cooled condenser driven by top-mounted compressor and fan; 1/5 HP. 115 VAC: 115°C thermal overload protector, 7.1 locked-rotor amps; 230 VAC: 120°C thermal overload protector, 7.6 A peak starting current; 3-sided wrap-around plate-type evaporator; Rigid foam insulation: 7.6 cm sides, 12.7 cm top, 15.2 cm bottom; Lockable door to prevent program tampering; Recovery Time: in an active cooling cycle, sampler temperature returns to 4°C within 5 minutes after the door has been left open for one minute at an ambient temperature of 24°C; Pull-down time: 24°C to 4°C, 20 minutes; Temperature Control: 4°C (±0.8°C) |
| Suction Hose Outer Diameter | 1/4 inch and 3/8 inch ID PTFE-lined Polyethylene with protective outer cover, available in clear and black. |
| Diagnostics | View event and alarm logs as well as maintenance status |
| Data storage | SAMPLE HISTORY - Logs up to 4000 entries for sample time stamp, bottle number and sample status (success, bottle full, rinse error, user abort, distributor error, pump fault, purge failure, sample timeout, power failure and low main battery). MEASUREMENTS - Logs up to 325,000 entries for the selected measurement channels according to the selected logging interval. EVENTS - Can log up to 2000 entries in the Sample History log. Logs include Power On, Power Failure, Firmware Updated, Pump Fault, Distributor Arm Error, Low Memory Battery, Low Main Battery, User Enabled, User Disabled, Program Started, Program Resumed, Program Halted, Program Complete, Take Sample, Tubing Change Required, Sensor Communication Errors, Cooling Failed, Heating Failed, Thermal Error Corrected. |
| Part No. | Description | Product description | Base type | Power requirements (Voltage) | Sample container |
|---|---|---|---|---|---|
| ASA.XXXXXXXXXX | AS950 AWRS Automatic Sampler | AS950 AWRS Automatic Sampler | 4 mevsim | 115/230 V AC | SINGLE BOTTLE: (1) 10 L Glass or Polyethylene or 21 L Polyethylene. MULTIPLE BOTTLES: (2) 10 L Polyethylene or Glass, (4) 10 L Polyethylene or Glass, (8) 2.3 L Polyethylene or 1.9 L Glass, (12) 2 L Polyethylene, (24) 1 L Polyethylene or 350 mL Glass |
Request a quote for pricing and lead time; you can mention the part number you are interested in your message.
Documents open on the Hach website in a new tab.
The AS950 AWRS is a rugged, weatherproof sampler with an integrated refrigerator for applications that require temperature control to preserve samples. Every AS950 includes a peristaltic pump with spring-loaded rollers and a standard liquid detection sensor for best-in-class sample volume accuracy. A USB connection and an auxiliary port for pulse or 4-20 inputs are also standard. Factory-installed options include sensor ports for integrated Hach water quality, level or flow, a port for Modbus RS485 communication, or a rain gauge and an alternative non-contact liquid detection sensor. Finally, inputs and outputs can be expanded with the IO9001 for a single high-voltage relay and the IO9004 for a comprehensive set of analog and digital outputs and relays. The AS950 is fully configurable with all of these options, and many of the most popular combinations are pre-configured in the part numbers below.
Hach's AWRS cabinet is designed to withstand harsh environmental conditions while preserving sample integrity. The cabinet features:
• An energy-efficient, top-mounted compressor that vents heat outward instead of into the sampler cabinet
• An IP24-rated enclosure that keeps dirt and water out of the instrument
• An optional backup battery and controller compartment heater
Product code: ASA.XXXXXXXXXX