Hach · ASA.XXXXXXXXXX

All-Weather Samplers

The AS950 AWRS is a rugged, weatherproof sampler with an integrated refrigerator for applications that require temperature control to preserve samples.

Weight86 kg
AlarmConfigurable alarms shown on the status screen are recorded in the alarm logs under settings. Alarms can be used to record system diagnostics and events such as program end, sample complete, missed sample and full bottle. Channel alarms are set point alarms for logged measurements (channels) such as pH, level and supply voltage.
Base type4 mevsim
Boyutlar76 x 81 x 130 cm (30 x 32 x 51 in.)
Vertical LiftMaximum 8.5 m with 8.8 m of 3/8 inch vinyl intake hose, at sea level and 20 - 25 °C
Languagesen, fr, es, it, de, pt, zh, tr, hu, cz, pl, ro, hr, el, sl, sk, fi, ru, ja, ko
Status messagesDetects and reports to all systems which program is running, whether a sample was missed, when the next sample will be taken, how many samples remain, the number of logged channels, the last measurement time, available memory, the number of active channels, when alarms were triggered (if any), active sensors and cabinet temperature
Display1/4 VGA, Colour; auto-prompted/menu-driven program
Manual SamplingStarts sample collection independently of the running program
Power requirements (Hz)50/60 Hz
Power requirements (Voltage)115/230 V AC
Factory-installable optionsTWO SENSOR PORTS: can be used with Hach digital Differential pH, Hach digital AV9000 analyser with submerged area-velocity flow and/or Hach digital US9000 ultrasonic level sensors
Please contact your local Hach representative for details.
NON-CONTACT LIQUID DETECT for applications requiring full tubing replacement. Sample volume repeatability
RAIN/RS485 PORT: can be used with a Hach Rain Gauge (not included) or for RS485 communication
Warranty24 aylar
InputsOne 0/4-20 mA input for flow pacing
Intake rinseStrainers: PTFE and 316 Stainless Steel construction or all 316 stainless steel in standard sizes; high-velocity and low-profile for shallow applications. Purge: Automatic air purge before and after each sample; duration automatically compensated for changing intake line lengths. Rinse: Intake line automatically rinsed with source liquid 1 to 3 times before each sample. Retries on failure: If no sample is collected on the first attempt, the sample collection cycle is automatically repeated 1 to 3 times
Body materialLow-density polyethylene with UV inhibitor (Sampler)
MemorySample history: 4000 records; Data log: 325,000 records; Event log: 2000 records
HortumlarPump tubing: 9.5 mm ID x 15.9 mm OD Silicone. Intake tubing: 1.0 - 4.75 m minimum length, 1/4 inch or 3/8 inch ID Vinyl or 3/8 inch ID PTFE-lined Polyethylene with protective outer cover (black or clear)
Communication CapabilityUSB and optional RS485 (Modbus)
Operating modeContinuous or non-continuous
Lock FunctionAccess code protection prevents tampering with the instrument
Pollution degree2
User InterfaceMembrane switch keypad with 2 multi-function soft keys
User interfaceChinese, English, French, German, Italian, Spanish, Portuguese
What's in the box1 of each: AS950 Controller
ModelAS950 AWRS
Enclosure materialPC/ABS alloy, NEMA 4X, 6, IP68, corrosion and ice resistant (Controller)
Sampling intervalSelectable in single increments from 1 to 9999 flow pulses or in one-minute increments from 1 to 9999 minutes
Sampling modePacing: Time weighted, Flow weighted, Time schedule, Flow schedule, Event. Distribution: Single-bottle composite, multi-bottle composite, multi-bottle discrete, bottles per sample, samples per bottle, or a combination of bottles per sample and samples per bottle
Sampling triggerWhen a flow sensor, pH/temperature sensor or environmental monitoring unit is used and field-selectable limits are exceeded, sampling can be triggered by an upset condition
Sample volumeProgrammable in 10 mL increments from 10 to 10,000 mL
Sample volume accuracyTypical: ±5% of a 200 mL sample volume with: 4.6 m vertical lift, 4.9 m of 3/8 inch vinyl intake tubing, single bottle, full bottle shut-off at room temperature and 1524 m elevation
Sample Volume RepeatabilityTypical: ±5% of a 200 mL sample volume with: 4.6 m vertical lift, 4.9 m of 3/8 inch vinyl intake tubing, single bottle, full bottle shut-off at room temperature and 1524 m elevation
Sample containerSINGLE BOTTLE: (1) 10 L Glass or Polyethylene or 21 L Polyethylene. MULTIPLE BOTTLES: (2) 10 L Polyethylene or Glass, (4) 10 L Polyethylene or Glass, (8) 2.3 L Polyethylene or 1.9 L Glass, (12) 2 L Polyethylene, (24) 1 L Polyethylene or 350 mL Glass
Sample PumpHigh-speed peristaltic, dual-roller pump with 0.95 ID x 1.6 OD cm (3/8 inch ID x 5/8 inch OD) pump tubing; IP37 pump body, Polycarbonate cover
Sample transport velocity0.9 m/s with 4.6 m vertical lift, 4.9 m of 3/8 inch vinyl intake tubing, at 21°C and 1524 m elevation
Auto Shut-offMultiple Bottle Mode: After a full rotation of the distributor arm (unless Continuous Mode is selected). Composite Mode: After a preset number of samples from 1 to 999 has been delivered to the composite container, or upon full container.
Pump Flow Rate4.8 L/min at 1 m vertical with typical 3/8 inch intake tubing
Probes included?No
ProgramlarDual Programming: Up to 2 sample programs can be run consecutively, in parallel or by programmed day of the week, allowing a single sampler to work like multiple samplers
Rain Gauge InputNo
Clock±1 second per day at 25 °C
Sensor Ports1
CertificationscETLus (115 V, 60 Hz model), CE (230 V, 50 Hz model)
Controller: CE, KC, RCM
TemperatureOperating: AWRS: 0 – 50 °C with optional controller compartment heater; AWRS: -40 – 50 °C with controller compartment heater and AC battery backup; AWRS: -15 – 40 °C. Storage: -30 – 60 °C
Refrigeration components and plumbingAll copper tubing exposed to harsh conditions is insulated with conformal corrosion protection to prevent sweating and condensation
Refrigeration systemAir-cooled condenser driven by top-mounted compressor and fan; 1/5 HP. 115 VAC: 115°C thermal overload protector, 7.1 locked-rotor amps; 230 VAC: 120°C thermal overload protector, 7.6 A peak starting current; 3-sided wrap-around plate-type evaporator; Rigid foam insulation: 7.6 cm sides, 12.7 cm top, 15.2 cm bottom; Lockable door to prevent program tampering; Recovery Time: in an active cooling cycle, sampler temperature returns to 4°C within 5 minutes after the door has been left open for one minute at an ambient temperature of 24°C; Pull-down time: 24°C to 4°C, 20 minutes; Temperature Control: 4°C (±0.8°C)
Suction Hose Outer Diameter1/4 inch and 3/8 inch ID PTFE-lined Polyethylene with protective outer cover, available in clear and black.
DiagnosticsView event and alarm logs as well as maintenance status
Data storageSAMPLE HISTORY - Logs up to 4000 entries for sample time stamp, bottle number and sample status (success, bottle full, rinse error, user abort, distributor error, pump fault, purge failure, sample timeout, power failure and low main battery). MEASUREMENTS - Logs up to 325,000 entries for the selected measurement channels according to the selected logging interval. EVENTS - Can log up to 2000 entries in the Sample History log. Logs include Power On, Power Failure, Firmware Updated, Pump Fault, Distributor Arm Error, Low Memory Battery, Low Main Battery, User Enabled, User Disabled, Program Started, Program Resumed, Program Halted, Program Complete, Take Sample, Tubing Change Required, Sensor Communication Errors, Cooling Failed, Heating Failed, Thermal Error Corrected.

Product code: ASA.XXXXXXXXXX

Related products

IO9000 Modülü
Hach

IO9000 Module

IO9004 analog 0/4-20 mA outputs and inputs. The IO9004 offers 3 analog 0/4-20 mA outputs and 2 analog 0/4-20 mA inputs. The outputs transmit sample events or logged data to SCADA systems.

AS950 Peristaltic Samplers Details →
Soğutmalı Numune Alıcılar
Hach

Refrigerated Samplers

The AS950 refrigerated sampler is optimised for indoor applications that require temperature control to preserve samples.

ASR.XXXXXXXXXX Details →