| Ağırlık | Max. 35 kg |
| Akış Hızı | 100 - 300 mL/min |
| Analog çıkışlar | Active 0 - 20 mA (or 4 - 20 mA) max. 500 Ohm load, standard: 4, optional: 8 |
| Boyut (Y x G x D) | 740 mm x 500 mm x 340 mm |
| Çıkış | Optional: Claros Ethernet connection and Modbus TCP/IP Ethernet connector; LAN version; 10/100 Mbps or Profinet or Ethernet IP |
| Cihaz havası | Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air. Used to flush the instrument in corrosive environement. Min. 0.2 bar - Max. 0.5 bar |
| Demineralize su | Internal dilution option: Rinse water & Dilution water |
| Dijital çıkışlar | Profibus DP or Modbus RTU |
| Doğrulama | Automatic; Frequency freely programmable: 6 hours, 12 hours, daily, weekly |
| Doğruluk | Better than 2% full scale range for standard test solutions |
| Drenaj | Atmospheric pressure, vented, min. Ø 32 mm |
| Enerji | 100 - 240 VAC, 50/60 Hz Max. power consumption: 120 VA |
| Garanti | 24 aylar |
| Girişimler | Ions, e.g., nitrite (NO₂ˉ) ˃ 5 mg/L, sulfide (S²ˉ) ˃ 100 mg/L, and sulfite (SO₃²ˉ) interfere. Thiocyanate causes high results. Large quantities of colour and turbidity interfere. Fats, oil, proteins, surfactants and tar interfere. |
| Kalibrasyon | Automatic; 2-point; offset or slope; Frequency freely programmable: 6 hours, 12 hours, daily, weekly. Note: manufacturer recommends that a calibration is done when the reagents are replaced |
| Koruma sınıfı | IP44 |
| Kutudakiler | EZ1012sc Cyanide Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets and 2 x empty 2.5L Reagent Containers with Fittings (for Buffer and Chloramine Solution) and 1 x empty 2.5L Glass Reagent Contaner with Fittings (for Colour Solution) |
| Malzeme | Hinged part: Thermoform ABS, door: PMMA Wall section: Galvanised steel, powder coated |
| Numune akışı sayısı | Standard: 1 Optional accessory for 2, 4, or 8 sample streams |
| Numune basıncı | By external overflow vessel (open to atmospheric pressure) |
| Numune kalitesi | Maximum particle size 100 µm, < 0.1 g/L; Turbidity < 50 NTU |
| Numune sıcaklığı | 10 - 30 °C |
| Ölçüm aralığı | No Dilution 0.001 - 0.02 mg/L CN 0.002 - 0.05 mg/L CN 0.002 - 0.1 mg/L CN 0.005 - 0.2 mg/L CN Internal Dilution 0.025 - 1 mg/L CN 0.050 - 2 mg/L CN 0.125 - 5 mg/L CN 0.250 - 10 mg/L CN 0.375 - 15 mg/L CN 0.500 - 20 mg/L CN |
| Ölçüm metodu | Chloramine T colorimetric method, conforms with Standard Method APHA 4500-CN (E)
Colorimetric |
| Ölçüm süresi | No Dillution Default: 30 min. Continuous: 28 min. Internal Dilution Default: 31 min. Continuous: 31 min. |
| Ortam sıcaklığı | 10 - 30 °C ± 4 °C deviation at 5 - 95% relative humidity (non-condensing) |
| Otomatik temizleme | Yes; Frequency freely programmable: 6 hours, 12 hours, daily, weekly |
| Parametre | Cyanide |
| Reaktif gereksinimi | Keep between 10 - 30 °C |
| Röleler | 5 contacts, not user configurable: Malfuntion, maintenance, analysis ready, sample ready, sample ready (EZ9150) |
| Saptama limiti | No Dilution 0.001 - 0.02 mg/L CN: 0.001 mg/L 0.002 - 0.05 mg/L CN: 0.002 mg/L 0.002 - 0.1 mg/L CN: 0.002 mg/L 0.005 - 0.2 mg/L CN: 0.005 mg/L Internal Dilution 0.025 - 1 mg/L CN: 0.025 mg/L 0.05 - 2 mg/L CN: 0.05 0.125 - 5 mg/L CN: 0.125 mg/L 0.25 - 10 mg/L CN: 0.25 mg/L 0.375 - 15 mg/L CN: 0.375 mg/L 0.5 - 20 mg/L CN: 0.5 mg/L |
| Sertifikalar | CE, ETL certified to UL and CSA safety standards, UKCA |
| Toprak bağlantısı | Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm² |