FX6x0 Sample Filtration Systems
The FX610 and FX620 are lightweight sample filtration systems for the NH6000sc and include a sample pump and compressor integrated directly into the analyser.
The EZ sc Series Online Analysers offer multiple options to monitor Phosphate in water. Typical applications are wastewater, drinking water, steam & power generation, surface water.
| Weight | Max. 35 kg |
| Flow Rate | 100 - 300 mL/min |
| Dimensions (H x W x D) | 688 mm x 460 mm x 340 mm |
| Output | Optional: Claros Ethernet connection and Modbus TCP/IP Ethernet connector; LAN version; 10/100 Mbps or Profinet or Ethernet IP |
| Instrument air | Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air. Used to flush the instrument in corrosive environement. Min. 0.2 bar - Max. 0.5 bar |
| Demineralised water | Internal dilution option: Rinse water & Dilution water |
| Digital outputs | Profibus DP or Modbus RTU |
| Verification | Automatic; Frequency freely programmable: 6 hours, 12 hours, daily, weekly |
| Accuracy | Better than 2% full scale range for standard test solutions |
| Drenaj | Atmospheric pressure, vented, min. Ø 32 mm |
| Warranty | 24 aylar |
| Calibration | Automatic; 2-point; offset or slope; Frequency freely programmable: 6 hours, 12 hours, daily, weekly. Note: manufacturer recommends that a calibration is done when the reagents are replaced |
| Protection class | IP44 |
| Malzeme | Hinged part: Thermoform ABS, door: PMMA Wall section: Galvanised steel, powder coated |
| Number of sample streams | Standard: 1 Optional accessory for 2, 4, or 8 sample streams |
| Sample pressure | By external overflow vessel (open to atmospheric pressure) |
| Sample quality | Maximum particle size 100 µm, < 0.1 g/L; Turbidity < 50 NTU |
| Ambient temperature | 10 - 30 °C ± 4 °C deviation at 5 - 95% relative humidity (non-condensing) |
| Automatic cleaning | Yes; Frequency freely programmable: 6 hours, 12 hours, daily, weekly |
| Relays | 5 contacts, not user configurable: Malfuntion, maintenance, analysis ready, sample ready, sample ready (EZ9150) |
| Certifications | CE, ETL certified to UL and CSA safety standards, UKCA |
| Earth connection | Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm² |
| Part No. | Description | Product description | Parameter | Measuring range | Output |
|---|---|---|---|---|---|
| EZ1031.9800140T | EZ1031sc Phosphate Colorimetric Analyser, Yellow Method, 1 stream, 4x mA Output | EZ1031sc Phosphate Colorimetric Analyser, Yellow Method, 1 stream, 4x mA Output | Phosphate (vanadate yellow) | No Dilution 0.02 - 1 mg/L PO₄-P 0.05 - 2.5 mg/L PO₄-P 0.05 - 5 mg/L PO₄-P 0.1 - 10 mg/L PO₄-P Internal Dilution 0.5 - 50 mg/L PO₄-P 1 - 100 mg/L PO₄-P 2.5 - 250 mg/L PO₄-P 5 - 500 mg/L PO₄-P 7.5 - 750 mg/L PO₄-P 10 - 1000 mg/L PO₄-P | Optional: Claros Ethernet connection and Modbus TCP/IP Ethernet connector; LAN version; 10/100 Mbps or Profinet or Ethernet IP |
| EZ1032.9800140T | EZ1032sc Phosphate Colorimetric Analyser, Blue Method, 1 stream, 4x mA Output | EZ1032sc Phosphate Colorimetric Analyser, Blue Method, 1 stream, 4x mA Output | Phosphate (vandate blue) | No Dilution 0.001 - 0.1 mg/L PO₄-P 0.003 - 0.25 mg/L PO₄-P 0.003 - 0.5 mg/L PO₄-P 0.005 - 1 mg/L PO₄-P Internal Dilution 0.025 - 5 mg/L PO₄-P 0.050 - 10 mg/L PO₄-P 0.125 - 25 mg/L PO₄-P 0.250 - 50 mg/L PO₄-P 0.375 - 75 mg/L PO₄-P 0.500 - 100 mg/L PO₄-P | Optional: Claros Ethernet connection and Modbus TCP/IP Ethernet connector; LAN version; 10/100 Mbps or Profinet or Ethernet IP |
| EZ2732.980A140T | EZ2732sc Total Phosphorus Colorimetric Analyser, 1 stream, 4x mA Output | EZ2732sc Total Phosphorus Colorimetric Analyser, 1 stream, 4x mA Output | Phosphorus, total | No Dilution 0.005 - 1 mg/L PO 4 (T) Internal Dilution 0.025 - 5 mg/L PO 4 (T) 0.05 - 10 mg/L PO 4 (T) 0.125 - 25 mg/L PO 4 (T) 0.25 - 50 mg/L PO 4 (T) | Optional: Claros Ethernet connection and Modbus TCP/IP Ethernet connector; LAN version; 10/100 Mbps or Profinet or Ethernet IP |
Request a quote for pricing and lead time; you can mention the part number you are interested in your message.
Documents open on the Hach website in a new tab.
The EZ sc Series Online Analysers offer multiple options to monitor Phosphate in water. Typical applications are wastewater, drinking water, steam & power generation, surface water.
The EZ1000sc Series Analysers use colorimetric analysis to measure Phosphate:
- EZ1031sc Vanadate yellow method; standard measuring range: 0.1 - 10 mg/L PO₄-P
- EZ1032sc Molybdate blue method; standard measuring range: 0.005 - 1 mg/L PO₄-P
Options for EZ1000sc analysers include:
- Calibration to 10, 25 or 50% of standard range
- Internal dilution
Options for all analysers include:
- Multiple stream analysis (1-8 streams) reducing cost per sampling point
- Analogue and/or digital outputs for communication
Phosphate can also be measured in combination with Total Phosphorus. For this option please check the EZ7800 Series.